Couette Flow with Plane Fixed Wall

Direct Numerical Simulations by Kuroda et al.


Expand AllDataAll pages

Flow Description

Expand/Collapse Item

Flow in a channel, between a plane fixed wall and a plane moving wall. The distance between the two walls is 2delta.

Flow Characteristics

Re = Uwdelta/nu = 3000

DNS data are available for the developed flow of "intermediate type". partialU/partialy = 0 close to the moving wall (U does not follow the logarithmic law of the wall) is the main feature of the developed flow.

Flow Parameters

Air with a kinematic viscosity: nu = 1.5 × 10-5 m2/s.
Wall velocity: Uw.
Flow rate velocity: Uq.
Friction velocity on fixed wall: utauf
Friction velocity on moving wall: utaum
Non-dimensional pressure gradient: a = (delta/rhoUw2) partialp/partialx = -1.33 × 10-3

Simulation Details

Expand/Collapse Item

Available Data

Expand/Collapse Item

Previous and Reference Numerical Solutions

Expand/Collapse Item

References

Expand/Collapse Item